Guys
What is the best way to ground this?
Clean all paint off all 4 mounting points, splash guard and frame brackets.... OR....1x Mounting point.
Or use a grounding strap?
Any help would be appreciated.
Regards
Nic
M38A1 Voltage Regulator Grounding
-
Nic
- Contributor

- Posts: 118
- Joined: Wed Dec 02, 2009 6:00 pm
- Location: United Kingdom
- Contact:
M38A1 Voltage Regulator Grounding
1956 M38A1 Nekaf
- wesk
- Site Administrator

- Posts: 16467
- Joined: Sun Apr 03, 2005 6:00 pm
- Location: Wisconsin
- Contact:
The ground provided by the original 4 shock mount straps is more than adequate. Ensure their contact area is paint and corrosion free. The regulator is bonded to the generator through the shielding of it's harness. The generator is bonded to the chassis through the adjusting arm and the braided strap just below the generator mount. If these contact areas are kept free of paint and corrosion everything will function correctly.
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100
Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100
Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
-