M38A1 Voltage Regulator Grounding

Discussion topics on Willys Overland M series vehicles
Post Reply
Nic
Contributor
Contributor
Posts: 118
Joined: Wed Dec 02, 2009 6:00 pm
Location: United Kingdom
Contact:

M38A1 Voltage Regulator Grounding

Post by Nic »

Guys

What is the best way to ground this?

Clean all paint off all 4 mounting points, splash guard and frame brackets.... OR....1x Mounting point.

Or use a grounding strap?

Any help would be appreciated.

Regards

Nic
1956 M38A1 Nekaf
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16467
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

The ground provided by the original 4 shock mount straps is more than adequate. Ensure their contact area is paint and corrosion free. The regulator is bonded to the generator through the shielding of it's harness. The generator is bonded to the chassis through the adjusting arm and the braided strap just below the generator mount. If these contact areas are kept free of paint and corrosion everything will function correctly.
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
Nic
Contributor
Contributor
Posts: 118
Joined: Wed Dec 02, 2009 6:00 pm
Location: United Kingdom
Contact:

Post by Nic »

Thanks Wes for clearing that up.

Regards

Nic
1956 M38A1 Nekaf
Post Reply