Post by horse »

So the end of the story. Still waiting for the end of lockdown so I could get my meter tested, so in the meantime bought another and found it gave much the same reading.

Then running along in the jeep I noticed the Volt gauge was in the yellow all the time.

I tested in the normal way to find no increase in voltage so suspected the generator not putting out.

I then thought I would check the engine earth by taking apart and cleaning, also the fan/generator belt looked a bit slack so that was adjusted.

Ran the engine, no change, still in yellow.

Carried out the Full Field check of the generator from the end of the long cable which was no Volts. I did have a spark when I put the jumper wire onto the hot battery cable on the starter.

Put everything back together a bit despondent.

Started the engine and the Volt gauge when onto the pip after a few seconds.

I then tested the long term overcharging and got 27.9 volts, which is good.

Not sure which bit got her working but it works.

Thanks for the input
Last edited by horse on Tue May 26, 2020 11:35 am, edited 1 time in total.
1952 M38
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16459
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

Looks like the flashing of the field got the regulator/generator working. Good for you!
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
User avatar
horse
Active Member
Active Member
Posts: 218
Joined: Sat Sep 07, 2019 6:00 pm
Location: Yorkshire U.K.

Post by horse »

There is me thinking the flash was a bad thing.
1952 M38
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16459
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

The flash happens when the polarity of the generator's magnet is incorrect. The result is the switching of polarity to the correct orientation. This allows the regulator to properly control the output of the generator.
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
User avatar
horse
Active Member
Active Member
Posts: 218
Joined: Sat Sep 07, 2019 6:00 pm
Location: Yorkshire U.K.

Post by horse »

Thanks Wes.

Every day is a school day.