Radiator removal

Post by mckim »

I'm trying to pull the radiator out of my M38, but the fan is in the way. My solution the first time was to unbolt the fan, but that seems silly, especially considering that the maintenance manual says to simply:
Lift radiator assembly straight up, being careful not to rub it against the fan. When studs are clear of the frame front cross member, tip radiator forward at the top and remove from vehicle." (TM 9-8012 paragraph 122.a.6)
The problem is, I can't seem to pull the radiator straight up far enough for the studs to clear. The sheet metal surrounding the fan hits the fan.

Any suggestions?
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16469
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

Since you have an M38 simply loosening the bolts on each side of the grill where it attaches to the fenders will allow the grill to be tilted forward and if you disconnect the light electrical connectors you can lift the grill right out of the way.

Don't forget to free the radiator from the two support rods at each side on the bottom that fasten to the front engine mounts.
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
User avatar
mckim
Contributor
Contributor
Posts: 63
Joined: Thu Jan 06, 2011 6:00 pm
Location: Idaho Falls, ID
Contact:

Post by mckim »

I've already removed the grill and pulled the radiator free from the support rods. I can pull it up and the top is free to swing forward until the tips of the fan blades hit the bottom of the shroud. I've aligned the fan to provide the most clearance.
Image
The ovals show the two areas where the parts are trying to inhabit the same space at the same time. The radiator is lifted and tilted forward for this photo.
User avatar
Bretto
Jeep Legend
Jeep Legend
Posts: 1390
Joined: Tue Nov 23, 2010 6:00 pm
Location: Orem, UT

Post by Bretto »

I didn't have any luck either till I pulled the fan off.
User avatar
sonny
Contributor
Contributor
Posts: 136
Joined: Sat Jul 04, 2009 6:00 pm
Location: Mooresville, North Carolina
Contact:

Post by sonny »

Same here, I had to remove the fan
1951 M38, 1952 M38, 1952 M100,1946 Bantam T3-C, RT-66/GRC, PP-112/GR, MT-299, DT-44 Mine Detector, MVPA # 33068, PMVPA CO
User avatar
DJ
Jeep Enthusiast
Jeep Enthusiast
Posts: 289
Joined: Thu Apr 14, 2005 6:00 pm
Location: Wis.

Post by DJ »

Me too!! I thought I had an odd pump or fan ,as I too had to remove the fan to remove the radiator.
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16469
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

I was just reviewing the service manual for the 6 pilot model M38's and I noticed the cooling fan shroud seems a bit narrower then the production M38 shrouds. Perhaps the 8012 instructions are predicated on the pilot models.

However when I read the TM 9-804 (first M38 ops and service manual) it lists the radiator removal in par 130a and adds one sentence that the 8012 does not have " Remove the fan by removing the four attaching bolts to the fan hub."
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
User avatar
mckim
Contributor
Contributor
Posts: 63
Joined: Thu Jan 06, 2011 6:00 pm
Location: Idaho Falls, ID
Contact:

Post by mckim »

wesk wrote:However when I read the TM 9-804 (first M38 ops and service manual) it lists the radiator removal in par 130a and adds one sentence that the 8012 does not have " Remove the fan by removing the four attaching bolts to the fan hub."
OK, it's good to know we aren't crazy. I'll remove the fan.

Thanks,
Stuart