M38 - Condensor Failures

Discussion topics on Willys Overland M series vehicles
Post Reply
User avatar
j3shane
Member
Posts: 8
Joined: Tue Mar 31, 2015 6:00 pm

M38 - Condensor Failures

Post by j3shane »

I have an M38 converted to 12v, but still using gutted old mag (points and condensder still used with external 12V coil) with 24V type spark plugs and cables still in use. Ran fine for a couple years but needed new points recently. Replaced points, condenser, and distributor cap, rotor, and gapped points, timed engine, etc. Ran great for a few hours and then sputtered like crazy with any acceleration, almost acted like water in the gas, idle wasn't great either. After much reading I bought some more condensers from another provider and replaced. Bingo - ran great again - but same thing happened after a few hours of running. Any ideas on what the issue could be? Bad coil? Coil stated tit had internal resister, no external resistor needed, so bypassed. Old coil used the resistor so it is still there, just not in the circuit, so could easily be used if needed.

Thanks in advance
User avatar
oilleaker1
Jeep Enthusiast
Jeep Enthusiast
Posts: 973
Joined: Wed May 13, 2009 6:00 pm
Location: South Dakota

Post by oilleaker1 »

Check the voltage being supplied to the battery. If the regulator is letting too much voltage out and overcharging things, it can fry your points. John
User avatar
4x4M38
Jeep Legend
Jeep Legend
Posts: 3487
Joined: Thu May 29, 2014 6:00 pm
Location: Texas Hill Country

Post by 4x4M38 »

I can't tell if you are using a civvy distributor or the military.

IIRC, somebody sells a 12 volt coil that will fit into the 24 volt distributor.
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16462
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

Look for one of these issues:

1 - Operating voltage to coil too high.
2 - Shorted points. Look carefully at the insulator strap on the contact's lead attachment post.
4 - Check distributor bearing wear
5 - Bare or pinched wires inside the distributor.
6 - Point and/or plug gaps too wide.


On another note: I noticed these posts of yours are showing up first in our web sites administrative email system. Try to only post here on the boards. This is often a problem when using portable equipment like pads and phones to communicate with our web sites older format.
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
User avatar
j3shane
Member
Posts: 8
Joined: Tue Mar 31, 2015 6:00 pm

Post by j3shane »

Thanks Wes, will check on those things. I don't believe there is a voltage regulator on this Jeep. Would that cause it and should I add one? If so any recommendations on which one? Thanks
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16462
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

You said converted to 12 volt but you did not tell us which alternator or generator was used for the conversion. The so-called "One Wire" alternators have the regulators built in. The rest require a regulator mounted somewhere in the engine compartment. Pictures are ALWAYS WORTH A THOUSAND WORDS!
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
Post Reply